Sl.No Item Name Quantity
1 Supply Installation and Commisioning of Dark field defect inspection equipment – KLA PUMA 1Nos.
2 Supply Installation and commisioning of Surfscan- KLA SP1 TBI 1Nos.
3 Supply installation and commisioning of Asher- Mattson Aspen II 1Nos.
4 Supply Installation and Commisioning of Polymer strip equipment after VIA and metal etch, LAM DVI (DV24) 1Nos.
5 Supply Installation and Commisioning of Metal Sputter equipment, AMAT Endura 1Nos.
6 Supply Installation and commisioning of Bright Field defect inspection equipment, KLA 2367 PRO 1Nos.
7 Supply Installation and commisioning of Photoresist strip Pre diffusion clean ZETA VIPER 1Nos.
8 Supply installation and comisioning of Oxide etcher, LAM EXELAN 2300/TEL UNITY ME 1Nos.
9 CMOX1,CMP Oxide,1. In-situ end point system 1Nos.
10 CMOX1,CMP Oxide,2. POU Filter Upgrade 1Nos.
11 CMOX1,CMP Oxide,3. Upgradation of Slurry recirculation and delivery pump in MABAT (CDU 3000) Slurry Delivery System 1Nos.
12 CMOX1,CMP Oxide,4. Hard disk upgrade (from mechanical HDD to RAID SSD) 1Nos.
13 CMOX1,CMP Oxide,5. Upper Pneumatic Assembly (UPA) module upgrade 1Nos.
14 CMOX1,CMP Oxide,6. Upgrade from peristaltic pump to CLC for slurry loop 1Nos.
15 CMOX1,CMP Oxide,7. Slurry Injection System (SIS) 1Nos.
16 CMOX1,CMP Oxide,8. Upgrade Slurry/DIW main valve from 1 line to 3 line 1Nos.
17 CMWO1,CMP Tungsten,1. POU Filter Upgrade 1Nos.
18 CMWO1,CMP Tungsten,2. Upgradation of Slurry recirulation and delivery pump in MABAT Slurry Delivery System 1Nos.
19 CMWO1,CMP Tungsten,3. Hard disk upgrade (from mechanical HDD to RAID SSD) 1Nos.
20 CMWO1,CMP Tungsten,4. UPA (Upper Pneumatic Assembly) module upgrade 1Nos.
21 CMWO1,CMP Tungsten,5. Upgrade from peristaltic pump to CLC for slurry loop 1Nos.
22 CMWO1,CMP Tungsten,6. Slurry Injection System (SIS) 1Nos.
23 CMWO1,CMP Tungsten,7. Upgrade Slurry/DIW main valve from 1 line to 3 line 1Nos.
24 MTOP2,Film Thickness and Reflectance Measurement,1 Install Mini environment 1Nos.
25 MTOP2,Film Thickness and Reflectance Measurement,2. SMIF upgrade 1Nos.
26 MTOP2,Film Thickness and Reflectance Measurement,3. Wedge Calibration wafer 1Nos.
27 REML1,Metal Etcher (1 DPS ch and 1 ASP ch),1. chamber addition 1 DPS chamber and 1ASP chamber 1Nos.
28 REML1,Metal Etcher (1 DPS ch and 1 ASP ch),2. Change the existing 4.2Mb hard disk to flash drive 1Nos.
29 REML1,Metal Etcher (1 DPS ch and 1 ASP ch),3. Change the floppy drive to USB drive 1Nos.
30 REML1,Metal Etcher (1 DPS ch and 1 ASP ch),4. Existing Buffer CH Viewport window to be upgraded with sapphire glass 1Nos.
31 REPL1,Poly Si / STI Etcher,1. Upgradation of existing Dome Temp. Control Unit (DTCU) of both the Chambers ( Including Source Rf match) 1Nos.
32 REPL1,Poly Si / STI Etcher,2. Change the floppy drive to USB drive 1Nos.
33 REPL1,Poly Si / STI Etcher,3. EPD system with EP monitoring at the top of dome for one chamber (AA Etch) only 1Nos.
34 IMHE1,High Energy Implanter,1. Additional wafer Buffer Loader 1Nos.
35 IMHE1,High Energy Implanter,2. Software Upgrade (SunSystem Upgrade and Night backup recorder installation.) 1Nos.
36 TRMU1,Track MUV ,1. Additional - 1 Hot Plate (HHP) 1Nos.
37 TRMU1,Track MUV ,2. Temperature and Humidity Controller Upgrade 1Nos.
38 TRDU1,Track DUV,1. Upgrade PLC on Developer LDS 1Nos.
39 SNDU1,Scanner DUV,1. Installation of Quadrpole Aperture (Resolution improvement) 1Nos.
40 MTCD1,CD SEM,SMIF upgrade 1Nos.
41 CDHD1,HDP Oxide CVD (3 ch),1.Replace ETO RF generator for two chambers with ENI RF generators 1Nos.
42 CDHD1,HDP Oxide CVD (3 ch),2. Change the existing 4.2Mb hard disk to flash drive 1Nos.
43 CDHD1,HDP Oxide CVD (3 ch),3. Change the floppy drive to USB drive 1Nos.
44 CDTS1,PECVD TEOS ,1.Up-grade with RPS 1Nos.
45 CDTS1,PECVD TEOS ,2. SACVD chamber addition 1Nos.
46 CDTS1,PECVD TEOS ,3. Change the existing 4.2Mb hard disk to flash drive 1Nos.
47 CDTS1,PECVD TEOS ,4. Change the floppy drive to USB drive 1Nos.
48 SPCO1,Silicide PVD Sputter,1.Upgradation of Conventional Ti Chamber for TiN capability 1Nos.
49 SPCO1,Silicide PVD Sputter,2. Change the existing 4.2Mb hard disk to flash drive 1Nos.
50 SPCO1,Silicide PVD Sputter,3. Change the floppy drive to USB drive 1Nos.
51 SPLR1,Barrier Metal Deposition,1.High speed robot configuration 1Nos.
52 SPLR1,Barrier Metal Deposition,2. Change the existing 4.2Mb hard disk to flash drive 1Nos.
53 SPLR1,Barrier Metal Deposition,3. Change the floppy drive to USB drive 1Nos.
54 MTFR1,FTIR Spectroscopy,Upgradation for B,P, and Si-OH bond measurement capability. 1Nos.
55 WTSE1,Single Wafer Spin Processor,Chuck Upgrade in both module- Wafer edges can be better handle with upgraded Chuck. 1Nos.
56 WTSE1,Single Wafer Spin Processor,Upgradation of CDS to handle 200 Ltr drum for catering increase chemical consumption with increase capacity 1Nos.
57 WTSE1,Single Wafer Spin Processor,O3 generator upgrade 1Nos.
58 WTSE1,Single Wafer Spin Processor,Addition Heat exchanger for Med 2 1Nos.
59 SBXC1,Pod and Cassette Cleaner,PLC upgrade 1Nos.
60 SSRT1,Wafer Sorter - Wafer Start,Upgrade to wafer Back side reading 1Nos.
61 SSRT2,Wafer Sorter - Common Area,Upgrade to wafer Back side reading 1Nos.
62 WTPD1,Batch processing ,1.O3 generator 1Nos.
63 WTPD1,Batch processing ,2. Mega sonic generator 1Nos.
64 WTPD1,Batch processing ,3. CD upgrade 1Nos.
65 WTRS1,Batch processing ,1. CD upgrade 1Nos.
66 WTRS1,Batch processing ,2. Mega sonic generator 1Nos.
67 YEDR1,CP measurement upgraded for Computer hardware, Windows Operating Syasuremeupgraded for Compstem and Hard Disk Storage 1Nos.
68 YEOI1,Optical Inspection Station,1. Upgrade YEOI1 for Bevel Inspection 1Nos.
69 YEOI1,Optical Inspection Station,2. Optics needs to be upgraded for existing system 1Nos.
70 YESR1,SEM Review Station,1. IP computer 1Nos.
71 YESR1,SEM Review Station,2. HDD higher capacity for all computers 1Nos.
72 YESR1,SEM Review Station,3. EDX software and computer 1Nos.
73 YESR1,SEM Review Station,4. Optical Microscope replacement 1Nos.
74 YESR1,SEM Review Station,5. OS system upgrade (O2) 1Nos.
75 YEOR1,Optical Review Station,1. Optical module needs to be upgraded. 1Nos.
76 YEOR1,Optical Review Station,2. ADR software needs to be upgraded 1Nos.
77 YEOR1,Optical Review Station,3. Upgrade YEOI1 for Bevel Inspection 1Nos.
78 Supply and installation of MES, as per SOW given in the tender 1Nos.
79 Supply of IPs for NVM (Single Poly non-volatile memory, as per SOW and specifications given in the tender 1Nos.
80 Supply, Installation, testing and commissioning of Cleanroom modifications and Utilities for Equipment Movement 1Nos.
81 De-hook, Move out and Crate 2 old 8” Equipment and re-locate of old 8" Equipment (as per layout drawings given in the tender) 1Nos.